NETSCOUT OneTouch AT G2模塊失去了FI-7000 FiberInspector Pro的功能
發(fā)布日期:2018年07月24日
瀏覽次數(shù):9次
編輯:深圳連訊
NETSCOUT OneTouch AT G2模塊失去了FI-7000 FiberInspector ?Pro的功能。
深圳連訊達(dá)簡(jiǎn)單為您說(shuō)明:
1、如果你是FI-7000或者FI2-7000使用Onetouch AT 的模塊如果1TG2-3000,1TG2-1500的模塊,那么會(huì)就會(huì)變成一個(gè)Onetouch AT的網(wǎng)絡(luò)測(cè)試儀。
2、如果你把1TG2-3000,1TG2-1500的模塊取下來(lái),再裝FI-7000的視頻探頭,你將會(huì)發(fā)現(xiàn)他不在工作。
3、你需要用DSX2-8000或者DSX2-5000的模塊重裝。才能顯示FI-7000的功能。
If you insert a OneTouch AT module in the back of your FI-7000 (Versiv mainframe), the main frame is turned into an excellent network troubleshooting tool. However, when you remove the OneTouch AT module, the main frame still thinks it is a OneTouch AT and you no longer have the ability to carry out automated fiber inspection.
Putting a DSX-5000, CertiFiber Pro or OptiFiber Pro module in the back will return it to allow automated fiber inspection. If you do not have one of these modules, don’t worry.
- Power off the Versiv main frame
- Remove the OneTouch AT module
- Hold down the?HOME key.
- Keep it held down while you power on the mainframe.
- When you see the screen change from OneTouch AT to Versiv, let go of the HOME key.
Your FI-7000 is now operational again.